Obtención de compuesto de Ti – HA por sinterizado a baja temperatura.
Abstract—From the engineering point of view, one of the factors that determine the success of a metallic prosthesis in the process ofosteointegration is related to the implant material. In this sense, the study of the response of the organism to a strange body is somehowa description of the immunolo...
Guardado en:
| Autores principales: | , , |
|---|---|
| Formato: | Artículo revista |
| Lenguaje: | Español |
| Publicado: |
Facultad de Ciencias Exactas, Físicas y Naturales
2021
|
| Materias: | |
| Acceso en línea: | https://revistas.unc.edu.ar/index.php/FCEFyN/article/view/32233 |
| Aporte de: |
| Sumario: | Abstract—From the engineering point of view, one of the factors that determine the success of a metallic prosthesis in the process ofosteointegration is related to the implant material. In this sense, the study of the response of the organism to a strange body is somehowa description of the immunologic response of the organism to implanted materials. Since the forties, studies that describe the biologicalphenomena that take place when a strange body is introduce into the organism have been carried on. Among the several materials studied,titanium is the bio-inert material that does not develop inflammatory processes that does not generates rejection from the body. But, due toits resistance to corrosion it does not promotes osteointegration processes since there is no bond between the titanium and the bone-tissue.This work presents the results obtained in the development of a laboratory method to manufacture a titanium-based biomaterial that containshydroxyapatite as a bioactive agent using powder metallurgical technique. |
|---|