Determination of folic acid and its related substances of the ferrous fumarate and folic acid dispersible tablet by HPLC

The aim of the present study was to establish a method for the determination of folic acid and related substances content in dispersible tablets. Method: A Shim-pack VP-ODS C18 reversed phase column (4.6 mm × 250 mm) was used. The mobile phase consisted of methanol-phosphate buffer (20:80) with a pH...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Chen, Qiaoyun, Liu, Yang, Luo, Y.H., Luo, M., Luo, L.Y.
Formato: Articulo
Lenguaje:Inglés
Publicado: 2012
Materias:
Acceso en línea:http://sedici.unlp.edu.ar/handle/10915/20182
http://www.latamjpharm.org/resumenes/31/4/LAJOP_31_4_1_10.pdf
Aporte de:
Descripción
Sumario:The aim of the present study was to establish a method for the determination of folic acid and related substances content in dispersible tablets. Method: A Shim-pack VP-ODS C18 reversed phase column (4.6 mm × 250 mm) was used. The mobile phase consisted of methanol-phosphate buffer (20:80) with a pH of 6.3.The flow rate was 1.0 mL/min, and the detection wavelength was 277nm and the column temperature was 30 °C. Results: The calibration curve was linear in the range of 5~150 μg/mL (r = 0.9998) for folic acid. The minimal detection limit was 99.08 %, n = 9 and the related substances were well separated. This method resulted to be convenient, accurate, selective and reliable, and can be applied for the quality control of folic acid.