Electrochemical Quartz Crystal Impedance Study of Redox Hydrogel Mediators for Amperometric Enzyme Electrodes
Quartz crystal impedance around the resonant frequency at 10 MHz of a composite quartz crystal resonator has been studied simultaneously with cyclic voltammetry. A modified quartz crystal with a redox hydrogel (poly(allylamine)-ferrocene cross-linked with glucose oxidase) and immersed in liquid elec...
Publicado: |
1997
|
---|---|
Acceso en línea: | https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00032700_v69_n23_p4833_Etchenique http://hdl.handle.net/20.500.12110/paper_00032700_v69_n23_p4833_Etchenique |
Aporte de: |
id |
paper:paper_00032700_v69_n23_p4833_Etchenique |
---|---|
record_format |
dspace |
spelling |
paper:paper_00032700_v69_n23_p4833_Etchenique2023-06-08T14:24:09Z Electrochemical Quartz Crystal Impedance Study of Redox Hydrogel Mediators for Amperometric Enzyme Electrodes Quartz crystal impedance around the resonant frequency at 10 MHz of a composite quartz crystal resonator has been studied simultaneously with cyclic voltammetry. A modified quartz crystal with a redox hydrogel (poly(allylamine)-ferrocene cross-linked with glucose oxidase) and immersed in liquid electrolyte was used. Impedance parameters (Rf and XLf) of the surface redox gel film were obtained by fitting the resonator transfer function |Vo/Vi| vs ω to a BVD equivalent circuit and analyzed with the multiple nonpiezoelectric layer model of Martin. Two limiting hydrogel layers of the same composition were studied while oxidizing and reducing the ferrocene/ferricenium moieties attached to the swollen polymer backbone: thin and thick redox hydrogel films. For the thin films, the Sauerbrey approximation was valid. The mass/thickness and film viscosity changes that resulted from the anion and water exchange were evaluated while redox switching the polymer on the assumption of negligible storage modulus G′ and a density of 1. For thick gel layers, on the other hand, the penetration depth of the acoustic wave was far less than the film thickness, and a liquid-like behavior was apparent. Film storage modulus and film loss modulus were simultaneously evaluated with the cyclic voltammetry. 1997 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00032700_v69_n23_p4833_Etchenique http://hdl.handle.net/20.500.12110/paper_00032700_v69_n23_p4833_Etchenique |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
description |
Quartz crystal impedance around the resonant frequency at 10 MHz of a composite quartz crystal resonator has been studied simultaneously with cyclic voltammetry. A modified quartz crystal with a redox hydrogel (poly(allylamine)-ferrocene cross-linked with glucose oxidase) and immersed in liquid electrolyte was used. Impedance parameters (Rf and XLf) of the surface redox gel film were obtained by fitting the resonator transfer function |Vo/Vi| vs ω to a BVD equivalent circuit and analyzed with the multiple nonpiezoelectric layer model of Martin. Two limiting hydrogel layers of the same composition were studied while oxidizing and reducing the ferrocene/ferricenium moieties attached to the swollen polymer backbone: thin and thick redox hydrogel films. For the thin films, the Sauerbrey approximation was valid. The mass/thickness and film viscosity changes that resulted from the anion and water exchange were evaluated while redox switching the polymer on the assumption of negligible storage modulus G′ and a density of 1. For thick gel layers, on the other hand, the penetration depth of the acoustic wave was far less than the film thickness, and a liquid-like behavior was apparent. Film storage modulus and film loss modulus were simultaneously evaluated with the cyclic voltammetry. |
title |
Electrochemical Quartz Crystal Impedance Study of Redox Hydrogel Mediators for Amperometric Enzyme Electrodes |
spellingShingle |
Electrochemical Quartz Crystal Impedance Study of Redox Hydrogel Mediators for Amperometric Enzyme Electrodes |
title_short |
Electrochemical Quartz Crystal Impedance Study of Redox Hydrogel Mediators for Amperometric Enzyme Electrodes |
title_full |
Electrochemical Quartz Crystal Impedance Study of Redox Hydrogel Mediators for Amperometric Enzyme Electrodes |
title_fullStr |
Electrochemical Quartz Crystal Impedance Study of Redox Hydrogel Mediators for Amperometric Enzyme Electrodes |
title_full_unstemmed |
Electrochemical Quartz Crystal Impedance Study of Redox Hydrogel Mediators for Amperometric Enzyme Electrodes |
title_sort |
electrochemical quartz crystal impedance study of redox hydrogel mediators for amperometric enzyme electrodes |
publishDate |
1997 |
url |
https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00032700_v69_n23_p4833_Etchenique http://hdl.handle.net/20.500.12110/paper_00032700_v69_n23_p4833_Etchenique |
_version_ |
1768544251107344384 |