Laser instrument for determination of the degree of cleanliness in cold-rolled steel plate manufacturing

Cold-rolled steel plate emerges from the manufacturing process with a thin layer of residual dirt that has to be kept under control for two main reasons: It may be indicative of deviations from normal functioning in previous manufacturing stages and it may impair the effectiveness of downstream oper...

Descripción completa

Detalles Bibliográficos
Autores principales: Bilmes, Gabriel, Martínez, Oscar Eduardo, Pignotti, Alberto
Publicado: 2002
Materias:
Acceso en línea:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03270793_v32_n3_p263_Bilmes
http://hdl.handle.net/20.500.12110/paper_03270793_v32_n3_p263_Bilmes
Aporte de:
id paper:paper_03270793_v32_n3_p263_Bilmes
record_format dspace
spelling paper:paper_03270793_v32_n3_p263_Bilmes2023-06-08T15:33:09Z Laser instrument for determination of the degree of cleanliness in cold-rolled steel plate manufacturing Bilmes, Gabriel Martínez, Oscar Eduardo Pignotti, Alberto Acousto-optical devices Industrial laser applications Industrial research and development Lasers applications Acoustooptical devices Cold rolling Galvanizing Industrial research Laser applications Painting Plates (structural components) Steel plates Steel structures Cold-rolled steel plate emerges from the manufacturing process with a thin layer of residual dirt that has to be kept under control for two main reasons: It may be indicative of deviations from normal functioning in previous manufacturing stages and it may impair the effectiveness of downstream operations such as painting, galvani-zing, etc. Standard measurements of this residual dirt are based on not trustworthy laboratory sample measurements, outside the production line. We developed a method that allows on-line determina-tions of the cleanliness degree for the whole manufactured steel plate bobbin. Based on this method, we designed the first industrial instrument (ELMES I), which is now in operation at the final inspection line of the Siderar's plant at Ensenada (Buenos Aires). Fil:Bilmes, G.M. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Martínez, O.E. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Pignotti, A. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. 2002 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03270793_v32_n3_p263_Bilmes http://hdl.handle.net/20.500.12110/paper_03270793_v32_n3_p263_Bilmes
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
topic Acousto-optical devices
Industrial laser applications
Industrial research and development
Lasers applications
Acoustooptical devices
Cold rolling
Galvanizing
Industrial research
Laser applications
Painting
Plates (structural components)
Steel plates
Steel structures
spellingShingle Acousto-optical devices
Industrial laser applications
Industrial research and development
Lasers applications
Acoustooptical devices
Cold rolling
Galvanizing
Industrial research
Laser applications
Painting
Plates (structural components)
Steel plates
Steel structures
Bilmes, Gabriel
Martínez, Oscar Eduardo
Pignotti, Alberto
Laser instrument for determination of the degree of cleanliness in cold-rolled steel plate manufacturing
topic_facet Acousto-optical devices
Industrial laser applications
Industrial research and development
Lasers applications
Acoustooptical devices
Cold rolling
Galvanizing
Industrial research
Laser applications
Painting
Plates (structural components)
Steel plates
Steel structures
description Cold-rolled steel plate emerges from the manufacturing process with a thin layer of residual dirt that has to be kept under control for two main reasons: It may be indicative of deviations from normal functioning in previous manufacturing stages and it may impair the effectiveness of downstream operations such as painting, galvani-zing, etc. Standard measurements of this residual dirt are based on not trustworthy laboratory sample measurements, outside the production line. We developed a method that allows on-line determina-tions of the cleanliness degree for the whole manufactured steel plate bobbin. Based on this method, we designed the first industrial instrument (ELMES I), which is now in operation at the final inspection line of the Siderar's plant at Ensenada (Buenos Aires).
author Bilmes, Gabriel
Martínez, Oscar Eduardo
Pignotti, Alberto
author_facet Bilmes, Gabriel
Martínez, Oscar Eduardo
Pignotti, Alberto
author_sort Bilmes, Gabriel
title Laser instrument for determination of the degree of cleanliness in cold-rolled steel plate manufacturing
title_short Laser instrument for determination of the degree of cleanliness in cold-rolled steel plate manufacturing
title_full Laser instrument for determination of the degree of cleanliness in cold-rolled steel plate manufacturing
title_fullStr Laser instrument for determination of the degree of cleanliness in cold-rolled steel plate manufacturing
title_full_unstemmed Laser instrument for determination of the degree of cleanliness in cold-rolled steel plate manufacturing
title_sort laser instrument for determination of the degree of cleanliness in cold-rolled steel plate manufacturing
publishDate 2002
url https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03270793_v32_n3_p263_Bilmes
http://hdl.handle.net/20.500.12110/paper_03270793_v32_n3_p263_Bilmes
work_keys_str_mv AT bilmesgabriel laserinstrumentfordeterminationofthedegreeofcleanlinessincoldrolledsteelplatemanufacturing
AT martinezoscareduardo laserinstrumentfordeterminationofthedegreeofcleanlinessincoldrolledsteelplatemanufacturing
AT pignottialberto laserinstrumentfordeterminationofthedegreeofcleanlinessincoldrolledsteelplatemanufacturing
_version_ 1768542646382362624