Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E

Seven biliar acids have been studied using negative-ion FAB ionization techniques. Productions of each of them were obtained by MS/MS techniques using MIKES and B/E routines. Results were compared in order to optimize the analyses conditions and to apply them for the identification and quantificatio...

Descripción completa

Detalles Bibliográficos
Publicado: 1997
Acceso en línea:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03650375_v85_n1-2_p47_FernandezBieber
http://hdl.handle.net/20.500.12110/paper_03650375_v85_n1-2_p47_FernandezBieber
Aporte de:
id paper:paper_03650375_v85_n1-2_p47_FernandezBieber
record_format dspace
spelling paper:paper_03650375_v85_n1-2_p47_FernandezBieber2023-06-08T15:35:44Z Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E Seven biliar acids have been studied using negative-ion FAB ionization techniques. Productions of each of them were obtained by MS/MS techniques using MIKES and B/E routines. Results were compared in order to optimize the analyses conditions and to apply them for the identification and quantification of the complex mixtures isolated from human fluids. The profiling of this acids will allow the rapid diagnosis of inborn errors of peroxisomal function. 1997 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03650375_v85_n1-2_p47_FernandezBieber http://hdl.handle.net/20.500.12110/paper_03650375_v85_n1-2_p47_FernandezBieber
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
description Seven biliar acids have been studied using negative-ion FAB ionization techniques. Productions of each of them were obtained by MS/MS techniques using MIKES and B/E routines. Results were compared in order to optimize the analyses conditions and to apply them for the identification and quantification of the complex mixtures isolated from human fluids. The profiling of this acids will allow the rapid diagnosis of inborn errors of peroxisomal function.
title Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E
spellingShingle Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E
title_short Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E
title_full Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E
title_fullStr Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E
title_full_unstemmed Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E
title_sort comparison between fab ms/ms techniques for the trace of biliar acids: mikes vs. b/e
publishDate 1997
url https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03650375_v85_n1-2_p47_FernandezBieber
http://hdl.handle.net/20.500.12110/paper_03650375_v85_n1-2_p47_FernandezBieber
_version_ 1768546254253457408