Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E
Seven biliar acids have been studied using negative-ion FAB ionization techniques. Productions of each of them were obtained by MS/MS techniques using MIKES and B/E routines. Results were compared in order to optimize the analyses conditions and to apply them for the identification and quantificatio...
Publicado: |
1997
|
---|---|
Acceso en línea: | https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03650375_v85_n1-2_p47_FernandezBieber http://hdl.handle.net/20.500.12110/paper_03650375_v85_n1-2_p47_FernandezBieber |
Aporte de: |
id |
paper:paper_03650375_v85_n1-2_p47_FernandezBieber |
---|---|
record_format |
dspace |
spelling |
paper:paper_03650375_v85_n1-2_p47_FernandezBieber2023-06-08T15:35:44Z Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E Seven biliar acids have been studied using negative-ion FAB ionization techniques. Productions of each of them were obtained by MS/MS techniques using MIKES and B/E routines. Results were compared in order to optimize the analyses conditions and to apply them for the identification and quantification of the complex mixtures isolated from human fluids. The profiling of this acids will allow the rapid diagnosis of inborn errors of peroxisomal function. 1997 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03650375_v85_n1-2_p47_FernandezBieber http://hdl.handle.net/20.500.12110/paper_03650375_v85_n1-2_p47_FernandezBieber |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
description |
Seven biliar acids have been studied using negative-ion FAB ionization techniques. Productions of each of them were obtained by MS/MS techniques using MIKES and B/E routines. Results were compared in order to optimize the analyses conditions and to apply them for the identification and quantification of the complex mixtures isolated from human fluids. The profiling of this acids will allow the rapid diagnosis of inborn errors of peroxisomal function. |
title |
Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E |
spellingShingle |
Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E |
title_short |
Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E |
title_full |
Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E |
title_fullStr |
Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E |
title_full_unstemmed |
Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E |
title_sort |
comparison between fab ms/ms techniques for the trace of biliar acids: mikes vs. b/e |
publishDate |
1997 |
url |
https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03650375_v85_n1-2_p47_FernandezBieber http://hdl.handle.net/20.500.12110/paper_03650375_v85_n1-2_p47_FernandezBieber |
_version_ |
1768546254253457408 |