Drift Time Measurement in the ATLAS Liquid Argon Electromagnetic Calorimeter using Cosmic Muons

The ionization signals in the liquid argon of the ATLAS electromagnetic calorimeter are studied in detail using cosmic muons. In particular, the drift time of the ionization electrons is measured and used to assess the intrinsic uniformity of the calorimeter gaps and estimate its impact on the const...

Descripción completa

Detalles Bibliográficos
Publicado: 2010
Acceso en línea:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_14346044_v70_n3_p755_Multitudinario
http://hdl.handle.net/20.500.12110/paper_14346044_v70_n3_p755_Multitudinario
Aporte de:
id paper:paper_14346044_v70_n3_p755_Multitudinario
record_format dspace
spelling paper:paper_14346044_v70_n3_p755_Multitudinario2023-06-08T16:14:40Z Drift Time Measurement in the ATLAS Liquid Argon Electromagnetic Calorimeter using Cosmic Muons The ionization signals in the liquid argon of the ATLAS electromagnetic calorimeter are studied in detail using cosmic muons. In particular, the drift time of the ionization electrons is measured and used to assess the intrinsic uniformity of the calorimeter gaps and estimate its impact on the constant term of the energy resolution. The drift times of electrons in the cells of the second layer of the calorimeter are uniform at the level of 1.3% in the barrel and 2.8% in the endcaps. This leads to an estimated contribution to the constant term of (0.29 0.04 0.05 )% in the barrel and (0.54 0.04 0.06 )% in the endcaps. The same data are used to measure the drift velocity of ionization electrons in liquid argon, which is found to be 4.61±0.07 mm/μs at 88.5 K and 1 kV/mm. © 2010 CERN for the benefit of the ATLAS collaboration. 2010 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_14346044_v70_n3_p755_Multitudinario http://hdl.handle.net/20.500.12110/paper_14346044_v70_n3_p755_Multitudinario
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
description The ionization signals in the liquid argon of the ATLAS electromagnetic calorimeter are studied in detail using cosmic muons. In particular, the drift time of the ionization electrons is measured and used to assess the intrinsic uniformity of the calorimeter gaps and estimate its impact on the constant term of the energy resolution. The drift times of electrons in the cells of the second layer of the calorimeter are uniform at the level of 1.3% in the barrel and 2.8% in the endcaps. This leads to an estimated contribution to the constant term of (0.29 0.04 0.05 )% in the barrel and (0.54 0.04 0.06 )% in the endcaps. The same data are used to measure the drift velocity of ionization electrons in liquid argon, which is found to be 4.61±0.07 mm/μs at 88.5 K and 1 kV/mm. © 2010 CERN for the benefit of the ATLAS collaboration.
title Drift Time Measurement in the ATLAS Liquid Argon Electromagnetic Calorimeter using Cosmic Muons
spellingShingle Drift Time Measurement in the ATLAS Liquid Argon Electromagnetic Calorimeter using Cosmic Muons
title_short Drift Time Measurement in the ATLAS Liquid Argon Electromagnetic Calorimeter using Cosmic Muons
title_full Drift Time Measurement in the ATLAS Liquid Argon Electromagnetic Calorimeter using Cosmic Muons
title_fullStr Drift Time Measurement in the ATLAS Liquid Argon Electromagnetic Calorimeter using Cosmic Muons
title_full_unstemmed Drift Time Measurement in the ATLAS Liquid Argon Electromagnetic Calorimeter using Cosmic Muons
title_sort drift time measurement in the atlas liquid argon electromagnetic calorimeter using cosmic muons
publishDate 2010
url https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_14346044_v70_n3_p755_Multitudinario
http://hdl.handle.net/20.500.12110/paper_14346044_v70_n3_p755_Multitudinario
_version_ 1768545893716328448