Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E

Seven biliar acids have been studied using negative-ion FAB ionization techniques. Productions of each of them were obtained by MS/MS techniques using MIKES and B/E routines. Results were compared in order to optimize the analyses conditions and to apply them for the identification and quantificatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Fernandez Bieber, G.J., Seldes, A.M.
Formato: JOUR
Acceso en línea:http://hdl.handle.net/20.500.12110/paper_03650375_v85_n1-2_p47_FernandezBieber
Aporte de:
id todo:paper_03650375_v85_n1-2_p47_FernandezBieber
record_format dspace
spelling todo:paper_03650375_v85_n1-2_p47_FernandezBieber2023-10-03T15:27:48Z Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E Fernandez Bieber, G.J. Seldes, A.M. Seven biliar acids have been studied using negative-ion FAB ionization techniques. Productions of each of them were obtained by MS/MS techniques using MIKES and B/E routines. Results were compared in order to optimize the analyses conditions and to apply them for the identification and quantification of the complex mixtures isolated from human fluids. The profiling of this acids will allow the rapid diagnosis of inborn errors of peroxisomal function. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_03650375_v85_n1-2_p47_FernandezBieber
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
description Seven biliar acids have been studied using negative-ion FAB ionization techniques. Productions of each of them were obtained by MS/MS techniques using MIKES and B/E routines. Results were compared in order to optimize the analyses conditions and to apply them for the identification and quantification of the complex mixtures isolated from human fluids. The profiling of this acids will allow the rapid diagnosis of inborn errors of peroxisomal function.
format JOUR
author Fernandez Bieber, G.J.
Seldes, A.M.
spellingShingle Fernandez Bieber, G.J.
Seldes, A.M.
Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E
author_facet Fernandez Bieber, G.J.
Seldes, A.M.
author_sort Fernandez Bieber, G.J.
title Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E
title_short Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E
title_full Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E
title_fullStr Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E
title_full_unstemmed Comparison between fab MS/MS techniques for the trace of biliar acids: MIKES vs. B/E
title_sort comparison between fab ms/ms techniques for the trace of biliar acids: mikes vs. b/e
url http://hdl.handle.net/20.500.12110/paper_03650375_v85_n1-2_p47_FernandezBieber
work_keys_str_mv AT fernandezbiebergj comparisonbetweenfabmsmstechniquesforthetraceofbiliaracidsmikesvsbe
AT seldesam comparisonbetweenfabmsmstechniquesforthetraceofbiliaracidsmikesvsbe
_version_ 1807321670195609600