Multicomponent kinetic determination of Cu, Zn, Co, Ni and Fe at trace levels by first and second order multivariate calibration

A flow injection system coupled to a photodiode array spectrophotometer (FI-PDA) for the multicomponent kinetic determination of Cu, Zn, Co, Ni and Fe at trace levels is presented. The substitution reaction of metal-nitrilotriacetic complexes (M-NTA) by 4-(2-pyridilazo) resorcinol (PAR) instead of t...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor principal: Fernández, F.M
Otros Autores: Tudino, M.B, Troccoli, O.E
Formato: Capítulo de libro
Lenguaje:Inglés
Publicado: Elsevier 2001
Acceso en línea:Registro en Scopus
DOI
Handle
Registro en la Biblioteca Digital
Aporte de:Registro referencial: Solicitar el recurso aquí
LEADER 06725caa a22010337a 4500
001 PAPER-20653
003 AR-BaUEN
005 20230518205204.0
008 190411s2001 xx ||||fo|||| 00| 0 eng|d
024 7 |2 scopus  |a 2-s2.0-0035804792 
024 7 |2 cas  |a cobalt, 7440-48-4; copper, 15158-11-9, 7440-50-8; iron, 14093-02-8, 53858-86-9, 7439-89-6; nickel, 7440-02-0; nitrilotriacetic acid, 139-13-9, 28528-44-1; resorcinol, 108-46-3; zinc, 7440-66-6, 14378-32-6 
040 |a Scopus  |b spa  |c AR-BaUEN  |d AR-BaUEN 
030 |a ACACA 
100 1 |a Fernández, F.M. 
245 1 0 |a Multicomponent kinetic determination of Cu, Zn, Co, Ni and Fe at trace levels by first and second order multivariate calibration 
260 |b Elsevier  |c 2001 
270 1 0 |m Tudino, M.B.; Departamento de Quimica Inorganica, Analitica y Quimica Fisica/INQUIMAE, Facultad de Ciencias, Capital Federal, Argentina; email: tudino@q1.fcen.uba.ar 
506 |2 openaire  |e Política editorial 
504 |a Gemperline, P.J., (1989) J. Chemometr., 3, p. 549 
504 |a Thomas, E.V., (1994) Anal. Chem., 66 (15), pp. 795A 
504 |a Mottola, H.A., (1988) Kinetic Aspects of Analytical Chemistry, , Wiley, New York 
504 |a Jordan, R.B., (1991) Reaction Mechanisms of Metallic and Organometallic Systems, , Oxford University Press, New York 
504 |a Tanaka, M., Funashashi, S., Shirai, K., (1967) Anal. Chim. Acta, 39, p. 437 
504 |a Engström, E., Karlberg, B., (1996) J. Chemometr., 10, p. 509 
504 |a Engström, E., Jönebring, I., Karlberg, B., (1998) Anal. Chim. Acta, 371, p. 227 
504 |a Azubel, M., Fernández, F.M., Tudino, M.B., Troccoli, O.E., (1999) Anal. Chim. Acta, 398, p. 93 
504 |a Booksh, K.S., Kowalski, B.R., (1994) Anal. Chem., 66 (15), pp. 782A 
504 |a Martens, H., Naes, T., (1989) Multivariate Calibration, , Wiley, New York 
504 |a Sommer, L., Kubán, V., Langová, M., (1982) Fresenius Z. Anal. Chem., 310, p. 51 
504 |a Bro, R., (1996) J. Chemometr., 10, p. 47 
504 |a Massart, D.L., Vandeginste, B.G.M., Buydens, L.M.C., De Jong, S., Lewi, P.J., Smeyers-Verbeke, J., (1997) Handbook of Chemometrics and Qualimetrics, (PART B). , Elsevier, Amsterdam 
504 |a Lorber, N.M., Faber, B.R., Kowalski, (1997) Anal. Chem., 69, p. 1620 
504 |a Xu, L., Schechter, I., (1997) Anal. Chem., 69, p. 3722 
504 |a Faber, N.M., (1998) Anal. Chem., 70, p. 5108 
504 |a López-Cueto, G., Ostra, M., Ubide, C., (2000) Anal. Chim. Acta, 405, p. 285 
504 |a Shuman, M.S., Shain, I., (1969) Anal. Chem., 41 (13), p. 1818 
504 |a Valcárcel, M., Luque de Castro, M.D., (1987) Flow-Injection Analysis, , Ellis Horwood, Chichester 
504 |a Linares, P., Luque de Castro, M.D., Valcarcel, M., (1985) Anal. Chem., 57, p. 2101 
504 |a Betteridge, D., Fields, B., (1983) Z. Anal. Chem., 314, p. 386 
504 |a Dahl, J.H., Espersen, D., Jensen, A., (1979) Anal. Chim. Acta, 105, p. 327 
504 |a Boqué, R., Rius, F.X., (1996) Chemometr. Intell. Lab. Syst., 32, p. 11 
504 |a Messick, N.J., Kalivas, J.H., Lang, P.M., (1996) Anal. Chem., 68, p. 1572 
504 |a Faber, N.M., (1998) Anal. Chem., 70, p. 5108 
504 |a Faber, N.M., Lorber, A., Kowalski, B.R., (1997) J. Chemometr., 11, p. 419 
504 |a Lin, Z., Booksh, K.S., Burguess, L.W., Kowalski, B.R., (1994) Anal. Chem., 66, p. 2552 
504 |a Gui, M., Rutan, S.C., Agbodjan, A., (1995) Anal. Chem., 67, p. 3293 
520 3 |a A flow injection system coupled to a photodiode array spectrophotometer (FI-PDA) for the multicomponent kinetic determination of Cu, Zn, Co, Ni and Fe at trace levels is presented. The substitution reaction of metal-nitrilotriacetic complexes (M-NTA) by 4-(2-pyridilazo) resorcinol (PAR) instead of the direct complexation of the free ions with PAR is employed. In this way, the spectral differences between the colored complexes are combined with the different reaction rates of the ions producing a more specific λ-time region for each metal enhancing the selectivity. Since the NTA-M-PAR system is fast and the pure analyte profiles appear partially overlapped in the time and λ-axis, temporal and spectral information were added to PLS and PCR models to improve results and to increase the number of metals to be determined. The developed method provides the fast and cheap determination of the five metals at the sub-ppm range and demonstrates that the use of temporal and spectral information increases the number of analytes to be simultaneously determined, improving the analytical figures of merit as well. © 2001 Elsevier Science B.V.  |l eng 
536 |a Detalles de la financiación: To UBACyT and INQUIMAE for partial financial support. 
593 |a Laboratorio De Análisis De Trazas, Departamento De Quimica Inorganica, Analitica Y Quimica Fisica/INQUIMAE, Facultad De Ciencias Exactas Y Naturales, Capital Federal, Argentina 
690 1 0 |a CO 
690 1 0 |a CU 
690 1 0 |a FE 
690 1 0 |a FIGURES OF MERIT 
690 1 0 |a FLOW INJECTION 
690 1 0 |a MULTICOMPONENT KINETIC DETERMINATION 
690 1 0 |a MULTIVARIATE CALIBRATION 
690 1 0 |a NI 
690 1 0 |a PAR 
690 1 0 |a ZN 
690 1 0 |a COBALT 
690 1 0 |a COPPER 
690 1 0 |a IRON 
690 1 0 |a METAL 
690 1 0 |a NICKEL 
690 1 0 |a NITRILOTRIACETIC ACID 
690 1 0 |a RESORCINOL 
690 1 0 |a ZINC 
690 1 0 |a ARTICLE 
690 1 0 |a CALIBRATION 
690 1 0 |a CHEMICAL REACTION 
690 1 0 |a COMPLEX FORMATION 
690 1 0 |a FLOW INJECTION ANALYSIS 
690 1 0 |a FLOW KINETICS 
690 1 0 |a MULTIVARIATE ANALYSIS 
690 1 0 |a PRIORITY JOURNAL 
690 1 0 |a REACTION ANALYSIS 
690 1 0 |a REACTION TIME 
690 1 0 |a SPECTROPHOTOMETRY 
690 1 0 |a RICKETTSIA SP. PAR 
700 1 |a Tudino, M.B. 
700 1 |a Troccoli, O.E. 
773 0 |d Elsevier, 2001  |g v. 433  |h pp. 119-133  |k n. 1  |p Anal. Chim. Acta  |x 00032670  |w (AR-BaUEN)CENRE-133  |t Analytica Chimica Acta 
856 4 1 |u https://www.scopus.com/inward/record.uri?eid=2-s2.0-0035804792&doi=10.1016%2fS0003-2670%2800%2901380-5&partnerID=40&md5=9af7462eeaeb8b6d810f56ca53147f14  |y Registro en Scopus 
856 4 0 |u https://doi.org/10.1016/S0003-2670(00)01380-5  |y DOI 
856 4 0 |u https://hdl.handle.net/20.500.12110/paper_00032670_v433_n1_p119_Fernandez  |y Handle 
856 4 0 |u https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00032670_v433_n1_p119_Fernandez  |y Registro en la Biblioteca Digital 
961 |a paper_00032670_v433_n1_p119_Fernandez  |b paper  |c PE 
962 |a info:eu-repo/semantics/article  |a info:ar-repo/semantics/artículo  |b info:eu-repo/semantics/publishedVersion 
999 |c 81606