Procedure for direct measurement of Common Mode Rejection

To measure the Common Mode Rejection (CMR) of an amplifier, it is necessary to carry out the measurements of the implemented and finished circuit, and then perform the measurement of its behavior in real operating conditions. This measurement is necessary to evaluate the susceptibility to conducted...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Zothner, Enrique, Zola, Julio, Kelly, Juan
Formato: Artículo publishedVersion
Lenguaje:Español
Publicado: FIUBA 2018
Materias:
EMI
Acceso en línea:https://elektron.fi.uba.ar/elektron/article/view/27
https://repositoriouba.sisbi.uba.ar/gsdl/cgi-bin/library.cgi?a=d&c=elektron&d=27_oai
Aporte de:
id I28-R145-27_oai
record_format dspace
spelling I28-R145-27_oai2026-02-11 Zothner, Enrique Zola, Julio Kelly, Juan 2018-01-03 To measure the Common Mode Rejection (CMR) of an amplifier, it is necessary to carry out the measurements of the implemented and finished circuit, and then perform the measurement of its behavior in real operating conditions. This measurement is necessary to evaluate the susceptibility to conducted electromagnetic interferences (conducted EMI) on the amplifier. In this work, a procedure of direct measurement of the CMR of an amplifier without altering the circuit is described. The measurements are verified by simulation with PSpice. Para medir el Rechazo en Modo Común (CMR) de un amplificador, es necesario llevar a cabo las mediciones del circuito implementado y terminado, y entonces realizar la medición de su comportamiento en condiciones de funcionamiento real. Esta medición es necesaria para evaluar la susceptibilidad a las interferencias electromagnéticas conducidas (EMI conducidas) sobre el amplificador. En este trabajo, se describe un procedimiento de medición directa del CMR de un amplificador sin alterar el circuito. Las mediciones se verifican mediante simulación con PSpice. application/pdf text/html https://elektron.fi.uba.ar/elektron/article/view/27 10.37537/rev.elektron.2.1.27.2018 spa FIUBA https://elektron.fi.uba.ar/elektron/article/view/27/40 https://elektron.fi.uba.ar/elektron/article/view/27/154 Derechos de autor 2017 Julio Zola, Enrique Zothner, Juan Kelly Elektron Journal; Vol. 2 No. 1 (2018); 39-46 Revista Elektron; Vol. 2 Núm. 1 (2018); 39-46 Revista Elektron; v. 2 n. 1 (2018); 39-46 2525-0159 2525-0159 CMRR EMI Operational amplifier CMRR EMI amplificador operacional Procedure for direct measurement of Common Mode Rejection Procedimiento para medición directa del Rechazo de Modo Común info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion https://repositoriouba.sisbi.uba.ar/gsdl/cgi-bin/library.cgi?a=d&c=elektron&d=27_oai
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-145
collection Repositorio Digital de la Universidad de Buenos Aires (UBA)
language Español
orig_language_str_mv spa
topic CMRR
EMI
Operational amplifier
CMRR
EMI
amplificador operacional
spellingShingle CMRR
EMI
Operational amplifier
CMRR
EMI
amplificador operacional
Zothner, Enrique
Zola, Julio
Kelly, Juan
Procedure for direct measurement of Common Mode Rejection
topic_facet CMRR
EMI
Operational amplifier
CMRR
EMI
amplificador operacional
description To measure the Common Mode Rejection (CMR) of an amplifier, it is necessary to carry out the measurements of the implemented and finished circuit, and then perform the measurement of its behavior in real operating conditions. This measurement is necessary to evaluate the susceptibility to conducted electromagnetic interferences (conducted EMI) on the amplifier. In this work, a procedure of direct measurement of the CMR of an amplifier without altering the circuit is described. The measurements are verified by simulation with PSpice.
format Artículo
publishedVersion
author Zothner, Enrique
Zola, Julio
Kelly, Juan
author_facet Zothner, Enrique
Zola, Julio
Kelly, Juan
author_sort Zothner, Enrique
title Procedure for direct measurement of Common Mode Rejection
title_short Procedure for direct measurement of Common Mode Rejection
title_full Procedure for direct measurement of Common Mode Rejection
title_fullStr Procedure for direct measurement of Common Mode Rejection
title_full_unstemmed Procedure for direct measurement of Common Mode Rejection
title_sort procedure for direct measurement of common mode rejection
publisher FIUBA
publishDate 2018
url https://elektron.fi.uba.ar/elektron/article/view/27
https://repositoriouba.sisbi.uba.ar/gsdl/cgi-bin/library.cgi?a=d&c=elektron&d=27_oai
work_keys_str_mv AT zothnerenrique procedurefordirectmeasurementofcommonmoderejection
AT zolajulio procedurefordirectmeasurementofcommonmoderejection
AT kellyjuan procedurefordirectmeasurementofcommonmoderejection
AT zothnerenrique procedimientoparamediciondirectadelrechazodemodocomun
AT zolajulio procedimientoparamediciondirectadelrechazodemodocomun
AT kellyjuan procedimientoparamediciondirectadelrechazodemodocomun
_version_ 1859522242966192128