Adjustment tolerances for interferometers by amplitude division illuminated with partially coherent light
In this work a general expression is deduced for the mutual intensity function for amplitude division interferometers illuminated with partially coherent sources, where the optical path difference in the branches of the interferometer is taken into consideration. This expression is applied to the pa...
Guardado en:
Autores principales: | , |
---|---|
Formato: | JOUR |
Acceso en línea: | http://hdl.handle.net/20.500.12110/paper_09500340_v38_n5_p847_Iemmi |
Aporte de: |
id |
todo:paper_09500340_v38_n5_p847_Iemmi |
---|---|
record_format |
dspace |
spelling |
todo:paper_09500340_v38_n5_p847_Iemmi2023-10-03T15:49:41Z Adjustment tolerances for interferometers by amplitude division illuminated with partially coherent light Iemmi, C.C. Simon, J.M. In this work a general expression is deduced for the mutual intensity function for amplitude division interferometers illuminated with partially coherent sources, where the optical path difference in the branches of the interferometer is taken into consideration. This expression is applied to the particular case of Gaussian sources, and an equation for the tolerances for misadjustment of the interferometer is obtained. The parallel between an amplitude division interferometer and an equivalent optical system, analysed in a previous work, is extended to this example. © 1991 Taylor & Francis Group, LLC. Fil:Iemmi, C.C. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Simon, J.M. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_09500340_v38_n5_p847_Iemmi |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
description |
In this work a general expression is deduced for the mutual intensity function for amplitude division interferometers illuminated with partially coherent sources, where the optical path difference in the branches of the interferometer is taken into consideration. This expression is applied to the particular case of Gaussian sources, and an equation for the tolerances for misadjustment of the interferometer is obtained. The parallel between an amplitude division interferometer and an equivalent optical system, analysed in a previous work, is extended to this example. © 1991 Taylor & Francis Group, LLC. |
format |
JOUR |
author |
Iemmi, C.C. Simon, J.M. |
spellingShingle |
Iemmi, C.C. Simon, J.M. Adjustment tolerances for interferometers by amplitude division illuminated with partially coherent light |
author_facet |
Iemmi, C.C. Simon, J.M. |
author_sort |
Iemmi, C.C. |
title |
Adjustment tolerances for interferometers by amplitude division illuminated with partially coherent light |
title_short |
Adjustment tolerances for interferometers by amplitude division illuminated with partially coherent light |
title_full |
Adjustment tolerances for interferometers by amplitude division illuminated with partially coherent light |
title_fullStr |
Adjustment tolerances for interferometers by amplitude division illuminated with partially coherent light |
title_full_unstemmed |
Adjustment tolerances for interferometers by amplitude division illuminated with partially coherent light |
title_sort |
adjustment tolerances for interferometers by amplitude division illuminated with partially coherent light |
url |
http://hdl.handle.net/20.500.12110/paper_09500340_v38_n5_p847_Iemmi |
work_keys_str_mv |
AT iemmicc adjustmenttolerancesforinterferometersbyamplitudedivisionilluminatedwithpartiallycoherentlight AT simonjm adjustmenttolerancesforinterferometersbyamplitudedivisionilluminatedwithpartiallycoherentlight |
_version_ |
1807320917774172160 |