Electrochemical impedance biosensor for Chagas Disease diagnosis in clinical samples
Chagas disease (CD) is one of the main neglected tropical diseases, diagnosed mainly by serological tests performed in centralized laboratories, which severely limits the clinical management of the disease in communities with scarce resources. Herein, an electrochemical impedance biosensor for the d...
Guardado en:
Autores principales: | , , , , , , , |
---|---|
Formato: | Articulo |
Lenguaje: | Inglés |
Publicado: |
2022
|
Materias: | |
Acceso en línea: | http://sedici.unlp.edu.ar/handle/10915/156722 |
Aporte de: |
id |
I19-R120-10915-156722 |
---|---|
record_format |
dspace |
spelling |
I19-R120-10915-1567222023-08-24T04:06:20Z http://sedici.unlp.edu.ar/handle/10915/156722 Electrochemical impedance biosensor for Chagas Disease diagnosis in clinical samples Cisneros, José Sebastián Chain, Cecilia Yamil Daza Millone, María Antonieta Labriola, C. A. Scollo, K. Ruiz, A. M. Estrela, P. Vela, María Elena 2022-12 2023-08-23T14:48:31Z en Ciencias Exactas Biología immunosensor impedimetric sensor Chagas disease cruzipain self-assembled monolayers clinical samples Chagas disease (CD) is one of the main neglected tropical diseases, diagnosed mainly by serological tests performed in centralized laboratories, which severely limits the clinical management of the disease in communities with scarce resources. Herein, an electrochemical impedance biosensor for the detection of CD was developed for the first time using a cruzipain-based sensor surface. The protein, highly immunogenic and isolated from Trypanosoma cruzi, was immobilized over the surface of gold disc electrodes modified with 11-mercaptoundecanoic (MUA) and 6-mercapto-1-hexanol (MCH) self-assembled monolayers (SAMs). Reproducible sensor surfaces, yielding 38 ± 3% coverage as measured by Surface Plasmon Resonance, were obtained by amide coupling of 120 μg/mL cruzipain onto 1/10 MUA/MCH SAMs for 30 min. Under optimized operational conditions, the impedimetric immunosensor recognized specific interactions for anti-T. cruzi antibodies in 1/800 diluted human serum patient samples. The charge transfer resistance of the biosensors increases by ~18% in the presence of the positive samples, whereas the negative samples give rise to a negligible increase of around 6%. An excellent selectivity to clinical samples from patients infected with T. cruzi was obtained. The clear signal difference obtained for positive and negative clinical samples highlights the applicability of the sensors for the point-of-care diagnosis of CD. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas Articulo Articulo http://creativecommons.org/licenses/by/4.0/ Creative Commons Attribution 4.0 International (CC BY 4.0) application/pdf |
institution |
Universidad Nacional de La Plata |
institution_str |
I-19 |
repository_str |
R-120 |
collection |
SEDICI (UNLP) |
language |
Inglés |
topic |
Ciencias Exactas Biología immunosensor impedimetric sensor Chagas disease cruzipain self-assembled monolayers clinical samples |
spellingShingle |
Ciencias Exactas Biología immunosensor impedimetric sensor Chagas disease cruzipain self-assembled monolayers clinical samples Cisneros, José Sebastián Chain, Cecilia Yamil Daza Millone, María Antonieta Labriola, C. A. Scollo, K. Ruiz, A. M. Estrela, P. Vela, María Elena Electrochemical impedance biosensor for Chagas Disease diagnosis in clinical samples |
topic_facet |
Ciencias Exactas Biología immunosensor impedimetric sensor Chagas disease cruzipain self-assembled monolayers clinical samples |
description |
Chagas disease (CD) is one of the main neglected tropical diseases, diagnosed mainly by serological tests performed in centralized laboratories, which severely limits the clinical management of the disease in communities with scarce resources. Herein, an electrochemical impedance biosensor for the detection of CD was developed for the first time using a cruzipain-based sensor surface. The protein, highly immunogenic and isolated from Trypanosoma cruzi, was immobilized over the surface of gold disc electrodes modified with 11-mercaptoundecanoic (MUA) and 6-mercapto-1-hexanol (MCH) self-assembled monolayers (SAMs). Reproducible sensor surfaces, yielding 38 ± 3% coverage as measured by Surface Plasmon Resonance, were obtained by amide coupling of 120 μg/mL cruzipain onto 1/10 MUA/MCH SAMs for 30 min. Under optimized operational conditions, the impedimetric immunosensor recognized specific interactions for anti-T. cruzi antibodies in 1/800 diluted human serum patient samples. The charge transfer resistance of the biosensors increases by ~18% in the presence of the positive samples, whereas the negative samples give rise to a negligible increase of around 6%. An excellent selectivity to clinical samples from patients infected with T. cruzi was obtained. The clear signal difference obtained for positive and negative clinical samples highlights the applicability of the sensors for the point-of-care diagnosis of CD. |
format |
Articulo Articulo |
author |
Cisneros, José Sebastián Chain, Cecilia Yamil Daza Millone, María Antonieta Labriola, C. A. Scollo, K. Ruiz, A. M. Estrela, P. Vela, María Elena |
author_facet |
Cisneros, José Sebastián Chain, Cecilia Yamil Daza Millone, María Antonieta Labriola, C. A. Scollo, K. Ruiz, A. M. Estrela, P. Vela, María Elena |
author_sort |
Cisneros, José Sebastián |
title |
Electrochemical impedance biosensor for Chagas Disease diagnosis in clinical samples |
title_short |
Electrochemical impedance biosensor for Chagas Disease diagnosis in clinical samples |
title_full |
Electrochemical impedance biosensor for Chagas Disease diagnosis in clinical samples |
title_fullStr |
Electrochemical impedance biosensor for Chagas Disease diagnosis in clinical samples |
title_full_unstemmed |
Electrochemical impedance biosensor for Chagas Disease diagnosis in clinical samples |
title_sort |
electrochemical impedance biosensor for chagas disease diagnosis in clinical samples |
publishDate |
2022 |
url |
http://sedici.unlp.edu.ar/handle/10915/156722 |
work_keys_str_mv |
AT cisnerosjosesebastian electrochemicalimpedancebiosensorforchagasdiseasediagnosisinclinicalsamples AT chainceciliayamil electrochemicalimpedancebiosensorforchagasdiseasediagnosisinclinicalsamples AT dazamillonemariaantonieta electrochemicalimpedancebiosensorforchagasdiseasediagnosisinclinicalsamples AT labriolaca electrochemicalimpedancebiosensorforchagasdiseasediagnosisinclinicalsamples AT scollok electrochemicalimpedancebiosensorforchagasdiseasediagnosisinclinicalsamples AT ruizam electrochemicalimpedancebiosensorforchagasdiseasediagnosisinclinicalsamples AT estrelap electrochemicalimpedancebiosensorforchagasdiseasediagnosisinclinicalsamples AT velamariaelena electrochemicalimpedancebiosensorforchagasdiseasediagnosisinclinicalsamples |
_version_ |
1807221070437023744 |